Mid-Pressure Low Fouling RO Elements
+
  • Mid-Pressure Low Fouling RO Elements

Description

KeenSen HW-8040 is complex feedwater conditions. lt features a specialized fabrication process that enhances the membrane's hydrophilicity, charge properties, and surface roughness, reducing the growth and adsorption of contaminants and microorganisms. The 34mil feed spacer design minimizes fouling, reduces pressure drop, and simplifies cleaning, thereby extending the membrane's lifespan.

It is primarily used for treating water with salinity ranging from 5,000-20,000 mg/L,including reclaimed water, wastewater, RO concentrate. Typical applications include power plants, steel plant, electroplating, petrochemicals, coal chemicals, textile dyeing, and municipal wastewater treatment.

 

Features

  • Outstanding resistance to high TDS (Total Dissolved Solids)
  • Excellent salt rejection performance
  • High cleaning recovery rate
  • Exceptional fouling resistant capabilities

 

1. Model and Performance Parameters

Model

Active Area

ft 2 (m 2)

Concentrate Channel

Spacer mil

Permeate Flow Rate

GPD(m 3 /d)

Stabilized Salt
Rejection%

HW-8040

400(37.2)

34

8500(32.3)

99.70

 

2. Standard Test Conditions

Solution

Temperature (°C)

pH

Operating Pressure
psi(MPa)

Recovery (%)

5000mg/L NaCl

25

7.5-8.0

290(2.0)

15

Water production fluctuation range ±15%

 

3. Membrane element size and operating limits

Model

Length

Diameter

Pemeate Tube lnner Diameter

inch

mm

inch

mm

inch

mm

8040

40

1016

7.9

201

1.12

28.5

 

Maximum Operating Pressure

600psi(4.14MPa)

Operating Temperature Range

0-45℃

Maximum Feed Flow Rate

17.0m3 /h(8040)、3.6 m 3 /h (4040)

Maximum Feed SDI 15

5.0

Free Chlorine Tolerance

0.1mg/L

pH Range, Continuous Operation

2-12

pH Range, Short-Term Cleaning

1-13

Maximum Element Pressure Drop

15psi(0.1MPa)

 

Enhanced HW-8040.pdf   

Product classification

Fouling Resistant RO Membrane Elements

Keywords

Mid-Pressure Low Fouling RO Elements
+
  • Mid-Pressure Low Fouling RO Elements

Mid-Pressure Low Fouling RO Elements

HW-8040


The HW-8040 membrane product is an anti-fouling aromatic polyamide composite reverse osmosis membrane element developed by Keensen High-Tech for use under complex influent conditions. This series uses a special membrane-making process to improve the hydrophilicity, charge, and roughness of the membrane sheet, reducing the growth and adsorption of pollutants and microorganisms on the membrane surface during operation. The membrane element uses a 34mil wide flow channel design to reduce clogging, lower the membrane system pressure difference, and is easy to clean, extending the service life of the membrane element.


Get a quote

Note: Please leave your contact information,we will contact you as soon as possible!